The occupational hygienist has also given you the following results from personal monitoring over an 8 hour period for manganese exposure from welding fumes.

Measured concentration (mg/m3)Exposure time (hours)
0.60.5
1.81.5
2.02.0
1.13.0
2.61.0

 

  • Using WES 2016, look up the TWA (8hours) and STEL (15 mins).
  • Using the monitoring data, calculate the 8 hour time-weighted average for exposure on this day. Use the formula:  
    TWA= ∑ (Concentration of contaminant × exposure time in hours)/8
  • Comment on the effectiveness of overall control strategies in place, and give recommendations for further action, based on published guidelines and standards.


(500 - 600 words approx.)